Once you are connected to the DCP over wifi, and you go to http://192.168.4.1/advanced you have the choice of a few extra settings.
Don't change these unless you are instructed to do so by Harvst support team.
Wake on membrane power
Solar control units from version 11.1 upwards are configured to wake from the power button on the membrane panel as well as from the override/wake button. If this is causing repeated self-wake, you can turn it off so that the box only wakes from the override button.
Battery voltage
If your control unit has been reconfigured by Harvst to run from an external battery, then use this to determine the low-voltage and critical battery cut-off levels. If you're using a typical 12V leisure battery, then choose 12V and the values are as below:
- Low voltage (system will be alive but pump won't run) ... 11V
- Critical voltage (system will go straight to sleep) ... 9V
This will preserve the external battery life, in the same way as the device will manage an internal battery. Note that you'll need to provide some way of charging your external battery; the control unit will not do it for you.